Knowledge-Based Planning In Robotic Intracranial Stereotactic Radiosurgery Treatments

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS(2021)

引用 1|浏览1
暂无评分
摘要
Purpose To develop a knowledge-based planning (KBP) model that predicts dosimetric indices and facilitates planning in CyberKnife intracranial stereotactic radiosurgery/radiotherapy (SRS/SRT).Methods Forty CyberKnife SRS/SRT plans were retrospectively used to build a linear KBP model which correlated the equivalent radius of the PTV (r(eq_PTV)) and the equivalent radius of volume that receives a set of prescription dose (r(eq_Vi), where V-i = V-10%, V-20% horizontal ellipsis V-120%). To evaluate the model's predictability, a fourfold cross-validation was performed for dosimetric indices such as gradient measure (GM) and brain V-50%. The accuracy of the prediction was quantified by the mean and the standard deviation of the difference between planned and predicted values, (i.e., Delta GM = GM(pred) - GM(clin) and fractional Delta V-50% = (V-50%pred - V-50%clin)/V-50%clin) and a coefficient of determination, R-2. Then, the KBP model was incorporated into the planning for another 22 clinical cases. The training plans and the KBP test plans were compared in terms of the new conformity index (nCI) as well as the planning efficiency.Results Our KBP model showed desirable predictability. For the 40 training plans, the average prediction error from cross-validation was only 0.36 +/- 0.06 mm for Delta GM, and 0.12 +/- 0.08 for Delta V-50%. The R-2 for the linear fit between r(eq_PTV) and r(eq_vi) was 0.985 +/- 0.019 for isodose volumes ranging from V-10% to V-120%; particularly, R-2 = 0.995 for V-50% and R-2 = 0.997 for V-100%. Compared to the training plans, our KBP test plan nCI was improved from 1.31 +/- 0.15 to 1.15 +/- 0.08 (P < 0.0001). The efficient automatic generation of the optimization constraints by using our model requested no or little planner's intervention.Conclusion We demonstrated a linear KBP based on PTV volumes that accurately predicts CyberKnife SRS/SRT planning dosimetric indices and greatly helps achieve superior plan quality and planning efficiency.
更多
查看译文
关键词
Cyberknife, knowledge&#8208, based planning, stereotactic radiosurgery, stereotactic radiotherapy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要