Comparison of deuterium retention in tungsten exposed to deuterium plasma and gas

Nuclear Materials and Energy(2020)

引用 0|浏览7
暂无评分
摘要
•D retention in plasma exposure W is much higher than that of gas charging W.•D2 desorption temperature of plasma exposure W is lower than that of gas charging W.•Detrapping energy of D in gas charging W is 2.17 eV.•Detrapping energy of D in plasma exposure W is 1.04 eV.
更多
查看译文
关键词
Tungsten,Deuterium retention,Gas-charging,Plasma exposure,Thermal desorption spectroscopy