Temperature Distribution In A Finisher Pig Building With Hybrid Ventilation

BIOSYSTEMS ENGINEERING(2020)

引用 6|浏览4
暂无评分
摘要
The differences between temperatures in the animal occupied zone (AOZ) and temperatures measured by control system sensors are rarely explored. This experimental study quantifies the dry-bulb air temperature [hereinafter temperature] distribution inside a finisher pig building that combines natural ventilation through automatically controlled openings with a mechanical ventilation system. Year-long temperature data from 28 sensors located at 3 different heights in the building was analysed to help understand the temperature distributions and indicate the temperatures below or above an assumed optimal temperature range, defined as between 14 degrees C and 24 degrees C. Relatively large variations in the spatial temperature distribution were found, and they were higher in the vertical direction than in the longitudinal direction. The temperatures measured in the AOZ at 0.25 m height, were on average, 7 degrees C warmer than that at 1.5 m height. The AOZ temperature correlated better with temperatures measured at 0.7 m or 1.5 m height in the same pen than with temperatures measured in the AOZ at other pens. The analyses show that a proportional-integral based control system effectively counteracts the effects of outdoor wind conditions, and the control system is capable of maintaining the defined optimal temperature at the measurement height. However, the optimum temperatures at the measurement heights above AOZ do not correspond to the measured temperatures in the AOZ. (C) 2020 IAgrE. Published by Elsevier Ltd. All rights reserved.
更多
查看译文
关键词
Hybrid ventilation, Automatically controlled windows, Temperature distribution, Diurnal variation, Spatial variation, Animal housing
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要