Comparison of Voltage Divider In-phase and Quadrature Error Measurement Between NMIA and NIM

2020 Conference on Precision Electromagnetic Measurements (CPEM)(2020)

引用 0|浏览15
暂无评分
摘要
This paper describes the comparison of quadrature and in-phase error measurement using the NMIA Inductive Voltage Divider (IVD) and the NIM Resistive Voltage Divider (RVD) between NMIA and NIM. The IVD provides output to input voltage ratios of 0.001 to 0.01 with standard uncertainties between 0.008×10 -6 and 0.04×10 -6 at frequencies up to 1 kHz. An RVD of a series-parallel structure has been proposed by NIM. The RVD provides an output to input voltage ratio of 0.01 and has been self-calibrated with in-phase and quadrature standard uncertainties better than 4×10 -6 at frequencies up to 1 kHz. Both in in-phase and quadrature errors of the IVD and RVD have been compared at frequencies from 40 Hz to 1 kHz at the voltage ratio of 0.01. The measurement results show agreement within 2×10 -6 V/V for inphase errors and 2.5 μrad for quadrature errors at frequencies up to 1 kHz.
更多
查看译文
关键词
Inductive voltage divider,Resistive voltage divider,Quadrature errors,In-phase errors,Comparison