Temperature analysis in flighted rotary drums and the influence of operating parameters

J. Seidenbecher,F. Herz, C. Meitzner,E. Specht, S. Wirtz, V. Scherer, X. Liu

Chemical Engineering Science(2021)

引用 6|浏览13
暂无评分
摘要
•Experimental setup built up to measure axial, radial and circumferential temperature profiles in a flighted rotary drum.•Influence of operating parameters on the temperature drop during cooling is measured.•Increasing the filling degree leads to lower temperature drop rates.•Increasing the volumetric airflow rate up to 600 m3/h leads to slightly increased temperature drop rates.•Highest influence is seen for the rotational speed, whose increase leads to higher temperature drop rates.
更多
查看译文
关键词
Rotary drum,Flights,Heat transfer,Particles,Temperature distribution,Operating parameters