Background and Objectives To compare the detection rates of sentinel lymph nodes after converting the tracer technique from blue dye to indocyanine green (ICG).Methods Patients with uterine or cervical cancer were enrolled for sentinel lymph node (SLN) dissection. A total of 109 consecutive patients were analyzed and compared to a historical cohort of 109 consecutive patients with the sentinel blue dye technique. SLNs were analyzed by ultrastaging.Results The bilateral mapping rate of sentinel nodes was significantly higher with the ICG (78%; n = 85) compared to the blue dye tracer (61%; n = 67; p = .006). Neither the mean number of SLN nor the rate of low volume metastases showed significant differences between both cohorts. In the subgroup of endometrial cancer patients, the number of systematic lymph node dissection (LND) was significantly lower in the ICG cohort compared to the blue dye cohort (9% vs. 28%, p = .001).Conclusions ICG improved the detection rate of pelvic SLN compared to blue dye and may be considered as the superior technique. In clinical practice, the rate of systematic LND further decreased after incorporating SLN mapping with ICG. Reliable safety data are still pending.