Comparison of Patent Ductus Arteriosus Stent and Blalock–Taussig Shunt as Palliation for Neonates with Sole Source Ductal-Dependent Pulmonary Blood Flow: Results from the Congenital Catheterization Research Collaborative

CIRCULATION(2021)

引用 5|浏览5
暂无评分
摘要
Patent ductus arteriosus (PDA) stenting is an accepted method for securing pulmonary blood flow in cyanotic neonates. In neonates with pulmonary atresia and single source ductal-dependent pulmonary blood flow (SSPBF), PDA stenting remains controversial. We sought to evaluate outcomes in neonates with SSPBF, comparing PDA stenting and surgical Blalock–Taussig shunt (BTS). Neonates with SSPBF who underwent PDA stenting or BTS at the four centers of the Congenital Catheterization Research Collaborative from January 2008 to December 2015 were retrospectively reviewed. Reintervention on the BTS or PDA stent prior to planned surgical repair served as the primary endpoint. Additional analyses of peri-procedural complications, interventions, and pulmonary artery growth were performed. A propensity score was utilized to adjust for differences in factors. Thirty-five patients with PDA stents and 156 patients with BTS were included. The cohorts had similar baseline characteristics, procedural complications, and mortality. Interstage reintervention rates were higher in the PDA stent cohort (48.6% vs. 15.4%, p < 0.001).
更多
查看译文
关键词
Pulmonary atresia,PDA stent,Pulmonary artery
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要