Prediction Of Fluid Responsiveness By Stroke Volume Variation In Children Undergoing Fontan Operation

BIOMED RESEARCH INTERNATIONAL(2020)

引用 6|浏览3
暂无评分
摘要
Background. Fontan operation is a palliative medical procedure performed on children with single-ventricle defects. As postoperative success of the procedure largely depends on the preload volume, it is necessary to maintain an appropriate pressure gradient between the systemic vein and the left atrium to ensure the effective volume of systemic circulation. However, there is a lack of effective indexes to evaluate fluid responsiveness in Fontan patients. Stroke volume variation (SVV) is a dynamic hemodynamic parameter based on cardiopulmonary interaction in mechanical ventilation. This study is aimed at validating the sensitivity and specificity of SVV and central venous pressure (CVP) in assessing the fluid responsiveness of Fontan patients. Method. Sixty-four children with single ventricle who underwent modified Fontan operation between May 2018 and January 2020 were included in this study. Patients were administered 10 ml center dot kg(-1) albumin for fluid challenge within 10 min after cardiopulmonary bypass. Before and after fluid challenge, the invasive arterial pressure module was connected to MostCare (TM) equipment to collect the cardiac index (CI) and SVV dynamically in a time window of 30 s at a frequency of 1000 Hz. According to the range of CI change, patients with Delta CI >= 15% were classified into the responder (R) group and those with Delta CI<15% into the nonresponder (NR) group. Using SVV and CVP as indicators, the receiver operating characteristic (ROC) curve of the patients was established, and the area under curve (AUC), diagnostic threshold, sensitivity, and specificity were calculated. Results. The SVV values were 16.28% (25th and 75th percentiles 14.17%-19.24%) and 13.68% (25th and 75th percentiles 12.90%-15.89%) before and after fluid challenge treatment in responders, respectively, and the values were 18.60 +/- 1.83 mmHg before and 20.20 +/- 2.39 mmHg for CVP after treatment. The AUC of SVV was 0.74 (95% confidence interval (CI) 0.54-0.94, P<0.05), and the cutoff value was 16%, offering a sensitivity of 50% and a specificity of 91.7%. Meanwhile, the AUC of CVP was 0.70 (95% CI 0.50-0.92, P>0.05), and the cutoff value was 19.5 mmHg, offering a sensitivity of 58% and a specificity of 76%. Conclusion. SVV exhibited a good predictive value for fluid responsiveness in pediatric Fontan patients. Appropriate fluid therapy according to SVV could improve the cardiac function of such patients. Trial registration. This study was registered in Chinese Clinical Trail Registry on Jan 26, 2018. Registration number is . Registry URL is . This observational prospective study was approved by the Local Ethics Committee of Shanghai Children's Medical Center affiliated to Shanghai Jiao Tong University (SCMCIRB-K2017035).
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要