Recent improvements in beam orbit feedback at NSLS-II

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2020)

引用 5|浏览9
暂无评分
摘要
This paper discusses improvements made to the fast orbit feedback (FOFB) system at NSLS-II in 2019. We first characterized the system by measuring the transfer function and the closed-loop gain of the system. We also constructed a model to predict the performance, which was based on physical behaviors. After finding and fixing the sources of the latency, we improved the closed-loop gain’s bandwidth from 250 Hz to 400 Hz in the horizontal plane and 250 Hz to 300 Hz in the vertical plane. The orbit beam instability improved by 30% and 10% in the horizontal and vertical planes, respectively.
更多
查看译文
关键词
Fast orbit feedback,Synchrotron light source,NSLS-II