An effective digital pulse processing method for pile-up pulses in decay studies of short-lived nuclei

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2020)

引用 7|浏览59
暂无评分
摘要
With the charged-particle decay spectroscopy extended to the proton drip-line region, half-lives of nuclei of interest decrease rapidly. Consequently, severe signal piling-up resulting from the implanted ions and their successive decays in position sensitive detectors become more and more common. To extract the spectroscopic information from the pile-up pulses with good accuracy, a digital pulse analysis algorithm is presented in this paper and validated with the α decay of 219Th and the internal conversion electron decays of 210,211Ra isomers, all of which have ∼ μs half-lives. The results show that with proper baseline correction, standard pulse construction and plateau-region fitting etc., the spectroscopic information of overlapping signals with time separation down to 80 ns and amplitude of individual pile-up pulse down to 70 keV, can be readily extracted.
更多
查看译文
关键词
Pile-up pulse,Algorithm,α decay,Conversion electron,Energy resolution
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要