Accuracy and reliability of maxillary digital model (MDM) superimposition in evaluating teeth movement in adults compared with CBCT maxillary superimposition

SCIENTIFIC REPORTS(2020)

引用 17|浏览5
暂无评分
摘要
Superimposition of 3D maxillary digital dental models of different time points based on palatal vault region has been used to evaluate tooth movement during orthodontic treatment. This study evaluated the accuracy and reliability of 3D maxillary digital model (MDM) superimposition in adults by comparing it with CBCT maxillary superimposition. In CBCT maxillary superimposition, voxel-based superimposition was firstly conducted, and MDMs were matched with corresponding CBCT models (CBCT-MDM superimposition). MDM superimposition (palatal vault regional superimposition) were performed on another pair of pre- and posttreatment MDMs. The position and orientation of upper first molars (U6s) and upper central incisors (U1s) on the posttreatment MDMs were compared to assess the accuracy of the MDM superimposition methods. The reliability was validated in both MDM superimposition and CBCT maxillary superimposition. In terms of accuracy, the average linear deviations in U6 and U1 positions were less than ± 0.3 mm, the average angular deviations of U6s and U1s were less than ± 0.2°, both have no significant difference from zero. The ICCs for MDM superimposition ranged from 0.85 to 0.99. The ICCs for CBCT-MDM superimposition were larger than 0.99 in all items. MDM superimposition was an efficient, accurate and reliable method for evaluating teeth movement in adults, although its reliability is slightly lower than CBCT maxillary superimposition.
更多
查看译文
关键词
Dental diseases,Image processing,Software,Science,Humanities and Social Sciences,multidisciplinary
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要