Fault Location Method Research of Leaky Coaxial Cable Based on the Linear Frequency Modulation Pulse Compression

PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS(2016)

引用 0|浏览22
暂无评分
摘要
A new fault location method of leaky coaxial communication cable is proposed and demonstrated in the condition of experiment, which is based on linear frequency modulation pulse compression. The principle diagram of leaky cable fault location of linear frequency modulation pulse compression and its system composition are introduction. Experiment results are presented show that, in contrast to the single pulse reflection in which the coupling losses of single energy in the leaky cable transmission is larger, linear frequency modulation pulse compression can improve transmit signal energy and range resolution of fault point after pulse compression of its echo signal.
更多
查看译文
关键词
fault location,leaky coaxial communication cable,single pulse reflection,linear frequency modulation,pulse compression