A new low-profile anatomic locking plate for fixation of comminuted, displaced greater tuberosity fractures of the proximal humerus

Lang-Qing Zeng Mm,Yun-Feng Chen,Yu-Wen Jiang, Lu-Lu Zeng Mm,Xiao-Gang Miao,Wei-Guo Liang

Journal of Shoulder and Elbow Surgery(2021)

引用 3|浏览8
暂无评分
摘要
Background: Although various implants exist for the fixation of isolated greater tuberosity fractures, few implants are specifically designed for such fractures. The purpose of this study was to investigate the clinical and radiologic outcomes of open reduction internal fixation with a low-profile anatomic locking plate for comminuted greater tuberosity fractures of the proximal humerus.Methods: From November 2012 to February 2018, 24 patients with displaced and comminuted isolated greater tuberosity fractures were treated with the new low-profile anatomic locking plate. To determine clinical outcomes, we evaluated active range of motion; the visual analog scale pain score; the Constant-Murley score; the Disabilities of the Arm, Shoulder and Hand score; radiographs; and complications.Results: In all cases, a mean follow-up period of 29.3 months (range, 18-48 months) was completed. All patients achieved bone union with a mean healing time of 11.3 weeks (range, 8-16 weeks). The mean Constant-Marley score was 91.1 points (range, 69-100 points), with a rate of good to excellent results of 95.8%. The average Disabilities of the Ann, Shoulder and Hand score was 9.9 points (range, 2-25 points), and the mean visual analog scale pain score was 1.1 points (range, 0-4 points). Mean active forward flexion, abduction, external rotation, and internal rotation (level) were 157 degrees, 152 degrees, and 40 degrees, and T11, respectively. Postoperatively, 1 patient had persistent shoulder stiffness, and 1 patient had recurrence of shoulder dislocation because of a falling injury during badminton. No serious complications such as subacromial impingement, malunion, nonunion, loss of reduction, or implant failure occurred.Conclusions: The new low-profile anatomic locking plate was useful for the treatment of comminuted isolated greater tuberosity fractures as it provided reliable stability and satisfactory radiographic and functional results. The described technique is a simple and effective method and provides a new reliable option for the treatment of isolated greater tuberosity fractures. (C) 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
更多
查看译文
关键词
Level IV,Case Series,Treatment Study
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要