Modifying reusable elastomeric respirators to utilise breathing system filters with 3D printed adapters, a safe alternative to N95 during COVID 19

Dexter Chee Yuen Liu, Tai Hong Koo,Jackson Kai Kit Wong, Ying Hong Wong,Kitty Sau Chun Fung, Yung Chan, Huey Sing Lim

medRxiv(2020)

引用 2|浏览0
暂无评分
摘要
The COVID-19 pandemic has caused a worldwide shortage of personal protective equipment including N95 and FFP3 respirators. Reusable elastomeric respirators are suitable alternatives when used with compatible filters. These filters may be difficult to source and elastomeric respirators are not recommended for surgical use as the exhaled air is not filtered. Breathing system filters are routinely used in anaesthetic circuits to filter virus and bacteria. In this study, we designed 3D printed adapters that allowed elastomeric respirators to utilise breathing system filters and made simple modifications to the respirators to filter exhaled breaths. We then evaluated the performance and safety of our modified elastomeric respirators with quantitative fit tests. We recruited 8 volunteers to perform quantitative fit tests. Fit factors, respiratory rate and end-tidal carbon dioxide were recorded before and after wearing the modified respirators for 1 hour. All 8 volunteers obtained fit factors of 200+, the maximum achievable, for all tests exercises in all fit tests. The mean (range) end-tidal carbon dioxide was 4.5 (3.9-5.5) kPa and 4.6 (range 4.1-5.3) kPa before and after 1 hour of usage. The mean (range) respiratory rate was 16.5 (11-24) min-1 and 17.4 (15-22) min-1 before and after 1 hour of usage. Four (50%) did not experience any subjective discomfort while 2 (25%) reported pressure on the face, 1 (12.5%) reported exhalation resistance and 1 (12.5%) reported transient dizziness with exertion. Breathing system filters combined with properly fitted reusable elastomeric respirators is a safe alternative to N95 during the COVID-19 pandemic. ### Competing Interest Statement The authors have declared no competing interest. ### Funding Statement no external funding was received ### Author Declarations All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript. Yes All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived. Yes I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance). Yes I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable. Yes The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
更多
查看译文
关键词
reusable elastomeric respirators,breathing system filters,adapters
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要