Heparin Anti-Xa Activity, A Readily Available Unique Test To Quantify Apixaban, Rivaroxaban, Fondaparinux, And Danaparoid Levels

ANESTHESIA AND ANALGESIA(2021)

引用 9|浏览44
暂无评分
摘要
BACKGROUND:Despite their usefulness in perioperative and acute care settings, factor-Xa inhibitor-specific assays are scarcely available, contrary to heparin anti-Xa assay. We assessed whether the heparin anti-Xa assay can (1) be used as a screening test to rule out apixaban, rivaroxaban, fondaparinux, and danaparoid levels that contraindicate invasive procedures according to current guidelines (>30 ng center dot mL(-1), >30 ng center dot mL(-1), >0.1 mu g center dot mL(-1), and >0.1 IU center dot mL(-1), respectively), (2) quantify the anticoagulant level if found significant, that is, if it exceeded the abovementioned threshold.METHODS:In the derivation cohort then in the validation cohort, via receiver operating characteristics (ROC) curve analysis, we evaluated the ability of heparin anti-Xa assay to detect levels of factor-Xa inhibitors above or below the abovementioned safety thresholds recommended for an invasive procedure (screening test). Among samples with relevant levels of factor-Xa inhibitor, we determined the conversion factor linking the measured level and heparin anti-Xa activity in a derivation cohort. In a validation cohort, the estimated level of each factor-Xa inhibitor was thus inferred from heparin anti-Xa activity. The agreement between measured and estimated levels of factor-Xa inhibitors was assessed.RESULTS:Among 989 (355 patients) and 756 blood samples (420 patients) in the derivation and validation cohort, there was a strong linear relationship between heparin anti-Xa activities and factor-Xa inhibitors measured level (r = 0.99 [95% confidence interval {CI}, 0.99-0.99]). In the derivation cohort, heparin anti-Xa activity <= 0.2, <= 0.3, <0.1, <0.1 IU center dot mL(-1) reliably ruled out a relevant level of apixaban, rivaroxaban, fondaparinux, and danaparoid, respectively (area under the ROC curve >= 0.99). In the validation cohort, these cutoffs yielded excellent classification accuracy (>= 96%). If this screening test indicated relevant level of factor-Xa inhibitor, estimated and measured levels closely agreed (Lin's correlation coefficient close to its maximal value: 95% CI, 0.99-0.99). More than 96% of the estimated levels fell into the predefined range of acceptability (ie, 80%-120% of the measured level).CONCLUSIONS:A unique simple test already widely used to assay heparin was also useful for quantifying these 4 other anticoagulants. Both clinical and economic impacts of these findings should be assessed in a specific study.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要