Misplacement of a central venous catheter into azygos vein via the right internal jugular vein
JOURNAL OF VASCULAR ACCESS(2021)
摘要
For critically ill patients, central venous catheterization may not always be placed in a correct tip position, even when guided by ultrasound. A case of inadvertent catheterization into azygos vein is described.
更多查看译文
关键词
Right internal jugular vein, azygos vein, central venous catheter, misplacement, ultrasound