The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography

A M Schwarz, G M Hohenberger, P Grechenig, A Kerner,A Gänsslen,M Staresinic,B Bakota

Injury(2021)

引用 1|浏览5
暂无评分
摘要
•We evaluated a new technique in application of supraacetabular schanz screws without image intensifier guidance.•Respecting the anatomical landmarks, pre- and intraoperative fluoroscopy can be avoided.•According to the described anatomical data, we defined a 2–2–2–20–20 concept.•Starting with a 2 cm skin incision 2 cm distal and 2 cm medial to the ASIS with a drill angulation of 20° inferior and 20° lateral orientation.•Using this technique, all schanz screws could be sufficiently inserted without intraprocedural x-ray imaging.