The 2–2–2–20–20 concept for supraacetabular schanz screw insertion without additional radiography
Injury(2021)
摘要
•We evaluated a new technique in application of supraacetabular schanz screws without image intensifier guidance.•Respecting the anatomical landmarks, pre- and intraoperative fluoroscopy can be avoided.•According to the described anatomical data, we defined a 2–2–2–20–20 concept.•Starting with a 2 cm skin incision 2 cm distal and 2 cm medial to the ASIS with a drill angulation of 20° inferior and 20° lateral orientation.•Using this technique, all schanz screws could be sufficiently inserted without intraprocedural x-ray imaging.
更多查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要