Characterisation and performance of the PADME electromagnetic calorimeter

JOURNAL OF INSTRUMENTATION(2020)

引用 9|浏览95
暂无评分
摘要
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fixed target. The strategy is to look for the reaction e(+) + e(-) -> gamma + A', where A' is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state gamma. The missing four-momentum carried away by the A' can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADME's electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.
更多
查看译文
关键词
Calorimeters,Detector design and construction technologies and materials,Gamma detectors (scintillators, CZT, HPGe, HgI etc)