Proximal Femur Peri-Implant Fracture After Lateral Femur Locking Plate: A Report of 2 Cases.

JBJS case connector(2020)

引用 0|浏览2
暂无评分
摘要
The use of locking plate technology for fixation of distal femur periprosthetic fractures is a common treatment modality. Although much has been reported regarding healing and complication rates of distal femoral periprosthetic fractures, little has been reported about peri-implant fractures subsequent to treatment using locking plates. We propose the importance of developing a method of fixation to protect the entire femur in osteoporotic patients sustaining distal femur periprosthetic fractures at the index surgery to avoid this complication.