Leprosy Surveillance Study In A Highly Endemic Brazilian Area Using Leprosy Specific Serologic Tests And Ifn Gamma Whole Blood Assay

Aline do Carmo Gonçalves,Emerith Mayra Hungria,Aline Araújo Freitas, Samira Sékula-Bührer, Cassia Maria Gomes, Ana Cecília Coelho, Laura Branquinho Nascimento,Mariane Martins de Araújo Stefani

EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES(2020)

引用 2|浏览8
暂无评分
摘要
This surveillance study evaluated leprosy-serologic tests and the IFN gamma whole-blood-assay/WBA as adjunct diagnostic tools. Previously diagnosed leprosy index cases, intradomiciliary, peridomiciliary contacts from a Brazilian endemic area were enrolled during domiciliary visits. Physical evaluation was performed by trained nurses and leprosy diagnosis confirmed by expert dermatologist. ELISA detected IgM anti-PGL-I, IgG anti-LID-1, and IgM/IgG anti-ND-O-LID antibodies. Heparinized WBA plasma stimulated with LID-1, 46f+ LID-1, ML0276 + LID-1 (24 h, 37 degrees C, 5% CO2) was tested for human IFN gamma (QuantiFERON (R)-TB Gold/QFT-G; Qiagen). The survey included 1731 participants: 44 leprosy index cases, 64 intradomiciliary, 1623 peridomiciliary contacts. Women represented 57.7%, median age was 32 years, 72.2% had BCG scar. Leprosy prevalence was higher in intradomiciliary (8.57%) versus peridomiciliary contacts (0.67%), p < 0.001. Among 23 suspects, five leprosy cases were confirmed: 4 multibacillary/MB and 1 paucibacillary/PB. Leprosy incidence was 0.30%: 1.56% in intradomiciliary versus 0.25% in peridomiciliary (p = 0.028). Seropositivity rates were 1.9% to PGL-I, 4.9% to LID-1, and 1.0% to ND-O-LID. LID-1 positivity was higher in all groups; incident cases were LID-1 seropositive. ND-O-LID positivity was higher in intra- versus peridomiciliary contacts (p = 0.022). IFN gamma WBA (40 index cases. 19 suspects, 35 intradomiciliary, 74 peridomiciliary contacts) showed higher LID-1/WBA positivity in peridomiciliary contacts (p> 0.05); significant differences among groups were seen with 46f+ LID-1 but 0276 + LID-1 induced higher IFN gamma levels. Incident cases were LID-1 seropositive, while IFN gamma-WBA had marginal diagnostic application. As seropositivity indicates exposed individuals at higher risk of disease development, the utility of serologic screening for surveillance and prophylactic measures remains to be demonstrated.
更多
查看译文
关键词
Leprosy survey, PGL-I, LID-1, ND-O-LID, Serology, IFN gamma-whole-blood-assay
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要