Dynamic 4 DCT Angiography for Guiding Transarterial Chemoembolization : Impact on the Reduction of Contrast Material , Operator Radiation Exposure , Catheter Consumption , and Diagnostic Confidence Dynamische 4 DCT-Angiografie zur Planung der transarteriellen Chemoembolisation : Einfluss auf die Kon

semanticscholar(2018)

引用 0|浏览2
暂无评分
摘要
Purpose This study was carried out to investigate the impact of abdominal dynamic four-dimensional CT angiography (4D-CTA) for guiding transarterial chemoembolization (TACE) on the amount of contrast material used, operator radiation exposure, catheter consumption, and diagnostic confidence. Materials and Methods Written consent was waived for this IRB-approved retrospective study. 29 patients (20 men; mean age: 65.7 ± 11.5 years) with malignant liver lesions underwent 4D-CTA, prior to initial TACE. Time-resolved volume-rendering technique (VRT), maximum-intensity projection (MIP), and multiplanar reconstruction (MPR) series were reconstructed, enabling a direct selective catheterization of the tumorsupplying artery without prior conventional digital subtraction angiography (DSA). 29 patients (16 men; mean age: 69.4 ± 13.9) who underwent traditional TACE served as the control group. The amount of administered contrast media, operator radiation exposure, and catheter consumption during TACE were compared. Two radiologists assessed diagnostic confidence in the exclusion of portal vein thrombosis. Results 4D-CTA TACE resulted in a significant reduction in the amount of contrast media used, compared to traditional TACE (–61.0 ml/ –66.3 % intra-arterial, –12.8 ml/ –13.8 % overall; P < 0.001). The dose-area product indicating operator radiation exposure during intervention was reduced by 50.5 % (P < 0.001), and 0.7 fewer catheters on average were used (P = 0.063), while 4D-CTA data was available to guide TACE. Diagnostic confidence in the exclusion of portal vein thrombosis was significantly enhanced by 4D-CTA, compared to traditional DSA images (scores, 3.9 and 2.4, respectively; P < 0.001). Conclusion Dynamic 4D-CTA enables TACE with a substantially reduced amount of contrast material, decreases operator radiation exposure, and increases diagnostic confidence in the exclusion of portal vein thrombosis. Key points ▪ 4D-CTA prior to TACE decreases the amount of utilized contrast material. ▪ The intra-arterial fraction of contrast media can be reduced by two-thirds. ▪ The risk of CIN may be decreased by means of 4D-CTA TACE. ▪ Operator radiation exposure is lower using 4D-CTA for guiding TACE. ▪ 4D-CTA portography allows for a higher diagnostic confidence than conventional DSA images. Citation Format ▪ Albrecht MH, Vogl TJ, Wichmann JL et al. Dynamic 4D-CT Angiography for Guiding Transarterial Chemoembolization: Impact on the Reduction of Contrast Material, Operator Radiation Exposure, Catheter Consumption, and Diagnostic Confidence. Fortschr Röntgenstr 2018; 190: 513–520
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要