Op-eujc190233 1117..1123

Adriaan W. Schneider, Mark G. Hazekampa,Michel I. M. Versteegha, Arend de Weger, Eduard R. Holman, Robert J. M. Klautz,Eline F. Bruggemans,Jerry Braun

semanticscholar(2019)

引用 0|浏览1
暂无评分
摘要
OBJECTIVES: Repeat aortic valve interventions after previous stentless aortic valve replacement (AVR) are considered technically challenging with an increased perioperative risk, especially after full-root replacement. We analysed our experience with reinterventions after stentless AVR. METHODS: A total of 75 patients with previous AVR using a Freestyle stentless bioprosthesis (31 subcoronary, 15 root-inclusion and 29 full-root replacement) underwent reintervention in our centre from 1993 until December 2018. Periprocedural data were retrospectively collected from the department database and follow-up data were prospectively collected. RESULTS: Median age was 62 years (interquartile range 47–72 years). Indications for reintervention were structural valve deterioration (SVD) in 47, non-SVD in 13 and endocarditis in 15 patients. Urgent surgery was required in 24 (32%) patients. Reinterventions were surgical AVR in 16 (21%), root replacement in 51 (68%) and transcatheter AVR in 8 (11%) patients. Early mortality was 9.3% (n = 7), but decreased to zero in the past decade in 28 patients undergoing elective reoperation. Per indication, early mortality was 9% for SVD, 8% for non-SVD and 13% for endocarditis. Aortic root replacement had the lowest early mortality rate (6%), followed by surgical AVR (13%) and C O N V EN TI O N A L V A LV E O P ER A TI O N S VC The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/ by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com European Journal of Cardio-Thoracic Surgery 56 (2019) 1117–1123 ORIGINAL ARTICLE doi:10.1093/ejcts/ezz222 Advance Access publication 19 August 2019 transcatheter AVR (25%, 2 patients with coronary artery obstruction). Pacemaker implantation rate was 7%. Overall survival rate at 10 years was 69% (95% confidence interval 53–81%). CONCLUSIONS: Repeat aortic valve interventions after stentless AVR carry an increased, but acceptable, early mortality risk. Transcatheter valve-in-valve procedures after stentless AVR require careful consideration of prosthesis leaflet position to prevent obstruction of the coronary arteries.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要