Soft x-ray tomography measurements in the Wendelstein 7-X stellarator

C Brandt,J Schilling,H Thomsen, T Broszat,R Laube, T Schröder,T Andreeva,M N A Beurskens,S A Bozhenkov,K J Brunner, A Card, C Cordes, H Damm,G Fuchert, K Gallowski, R Gutzmann,J Knauer,H P Laqua, M Marquardt, Ph Nelde,U Neuner, E Pasch, K Rahbarnia, J Recknagel, M Schülke,E R Scott,T Sieber

PLASMA PHYSICS AND CONTROLLED FUSION(2020)

引用 17|浏览96
暂无评分
摘要
The soft x-ray tomography diagnostic in the stellarator Wendelstein 7-X consists of twenty pinhole cameras, up-down symmetrically arranged in a poloidal, triangular cross-section of the plasma vessel. The x-ray emissivity is measured with 16 bit amplitude resolution at 2 MHz sampling rate along 360 lines-of-sight by silicon photodiode arrays. In the recent operation campaign data acquisition (DAQ) has been working reliable for the conducted plasma pulse lengths <1 min, however the DAQ system are ready for the foreseen 30 min plasma pulse lengths of upcoming campaigns. The bandwidth of the preamplifiers is 200 kHz and the sensitive energy range is approximately 1-12 keV. The measurements indicate the up-down symmetric emissivity distribution in the triangular poloidal cross-section. First tomographic reconstructions of different magnetic field configurations are consistent with the theoretically calculated flux surface topology.
更多
查看译文
关键词
x-ray,tomography,XMCTS,stellarator,Wendelstein,W7-X
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要