Neutron spectroscopy & H*10 dosimetry with tensioned metastable fluid detectors

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2020)

引用 7|浏览5
暂无评分
摘要
This article discusses outcome of research for a novel, fast-to-thermal, continuous and pulsed neutron-spectroscopy enabled H*10 dosimetry capable (gamma-beta blind), high intrinsic efficiency sensor system utilizing the tensioned metastable fluid detector (TMFD) architecture. In our past studies the response matrix was developed in single-atom-spectroscopy mode due to which TMFD sensing fluids were limited to one with molecules for which only one atom was considered as causing detection for fast energy neutrons (>0.1 MeV). In this paper, we describe how these limitations were overcome using a new approach for determination of the response matrix — resulting in a generalized development of a neutron spectroscopy system for any arbitrary fluid, and for spectrometric detection of thermal and fast energy neutrons. Unlike for gamma-beta radiation where the dose weight-factor is invariant with energy, for neutrons it is highly non-linear with the induced dose per unit neutron flux increasing ∼100 times with neutron energy from eV to MeV; this must be accounted for to avoid significant conservatisms inherent in non-spectroscopic general purpose neutron detectors. The neutron spectrometry enablement for TMFDs was utilized to develop H*10-TMFD rapid, high efficiency neutron dosimetry for ultra-low (∼5 μRem/h) to high (potentially >10 Rem/h) environments, while remaining 100% gamma-beta blind. Comparisons were performed against the mainstay standard Bonner Sphere Spectrometer (BSS) in which, for 252Cf and Pu-Be/Am-Be isotope source neutron spectra the two systems offered results within +∕−10% of each other in >100 μRem/h fields. Notably, when under ultra-low (∼10 μRem/h) fields the BSS and other traditional detectors proved impractical (effectively dysfunctional); whereas, the H*TMFD system measured hard and soft neutron spectra to within +∕−5% of those from MCNP predictions of the same experiments. Comparisons were also made for monoenergetic D-D (2.45 MeV) neutron based radiation fields (∼20–30 mRem/h) for which the H*TMFD system successfully predicted both the H*-10 dose and spectrum nuance characteristics (including for the effect of tritium contamination caused 14 MeV component) whereas, the BSS system was unable to do so appropriately.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要