The reproducibility of trophectoderm biopsies in euploid, aneuploid, and mosaic embryos using independently verified next-generation sequencing (NGS): a pilot study

Journal of Assisted Reproduction and Genetics(2020)

引用 28|浏览31
暂无评分
摘要
Purpose To assess the accuracy and reliability of comprehensive chromosome screening by next-generation sequencing (NGS) of human trophectoderm (TE) biopsy specimens. Methods The reliability and accuracy of diagnoses made by preimplantation genetic testing for aneuploidy (PGT-A) from TE biopsy were tested. Repeat biopsies of TE and inner cell mass (ICM) samples were obtained from thawed blastocysts previously tested by NGS. To test for the reliability of the NGS assay, biopsy samples were compared with the original PGT-A results. Prior NGS testing classified the TE samples as euploid, aneuploid, or aneuploid-mosaic. The resulting re-biopsied samples underwent SurePlex whole genome amplification followed by NGS via the MiSeq platform, with copy number value (CNV) determined using BlueFuse Multi Software. The primary outcome measure was reliability, defined as concordance between initial TE result and the repeat biopsies. Accuracy was determined by concordance between the TE and ICM samples, and compared between three chromosome types (disomic, aneuploid, and mosaic). Results Re-biopsies were performed on 32 embryos with prior PGT-A showing euploidy (10 embryos), aneuploidy of one or two chromosomes (4 embryos), or aneuploid-mosaic with one aneuploid chromosome and one mosaic chromosome (18 embryos). One hundred twenty-nine biopsy samples completed NGS (90 TE and 39 ICM biopsies) and 105 biopsy results were included in the analysis. TE biopsies provide a highly accurate test of the future fetus, with the ICM disomic concordance rate of 97.6%. Clinical concordance rates indicate that TE biopsies provide a reliable test when the result is euploid (99.5%) or aneuploid (97.3%), but less reliable when the result is mosaic (35.2%). Conclusion TE biopsies predict euploidy or aneuploidy in the ICM with a high degree of accuracy. PGT-A with NGS of TE biopsies is shown to be highly reliable, with clinically relevant concordance rates for aneuploidy and euploidy over 95%. TE biopsies indicating mosaicism were less reliable (35.2%), presumably because mitotic non-disjunction events are not uniformly distributed throughout the blastocyst. However, classification of TE biopsy of PGT-A with NGS results as either aneuploid or euploid provides a highly reliable test.
更多
查看译文
关键词
Mosaic, Next-generation sequencing, Inner cell mass, Trophectoderm biopsy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要