Plate-related results of opening wedge high tibial osteotomy with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation: a retrospective case series of 346 knees

Claudia Hartz, Ralph Wischatta, Eckhardt Klostermeier, Malte Paetzold, Klaus Gerlach, Frank Pries

Journal of Orthopaedic Surgery and Research(2019)

引用 5|浏览0
暂无评分
摘要
Background While open wedge high tibial osteotomy (owHTO) is an established standard procedure to treat medial osteoarthritis of the knee in combination with varus deformity, it bears the risk of postoperative hardware failures and lateral cortical hinge fractures. This in turn can lead to an accelerated osteoarthritis, non-union, or a loss of correction accuracy. The purpose of the study was to evaluate the radiologic outcomes of owHTO with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation in patients with medial osteoarthritis and varus deformity. Methods Three hundred twenty-four consecutive patients (346 knees) who were treated with owHTO using the PEEKPower HTO plate were included in this retrospective study; 89.9% of the patients were overweight or obese. Patients were followed by conventional radiographs over a 12-month period. Typical plate-related results such as the time and quality of gap healing as well as the correction accuracy were analyzed. Furthermore, the number of lateral cortex fractures was determined. Results Bony consolidation was observed after a mean gap healing time of 4.0 ± 1.7 months independent on the patients’ weight ( p = 0.2302). With increasing gap sizes, bony healing was significantly prolonged ( p < 0.001). Additionally, patients with greater gap sizes had a significantly increased risk for a lateral cortex fracture ( p = 0.0041). However, none of the patients had a non-union 1 year postoperative. A hinge fracture occurred in 30% of patients. Hinge fractures with Takeuchi grades I and II increased the gap healing time compared to no fracture ( p = 0.0069 and p = 0.0002, respectively), but only 1.2% of patients with hinge fracture had a clinical relevant loss of correction ≥ 3 mm. No implant failures were found. Conclusions Open wedge HTO using the PEEKPower HTO plate for patients with medial osteoarthritis of the knee in combination with tibial varus deformity leads to excellent bony consolidation also in cases with a hinge fracture, a gap size > 12 mm as well as for severely obese patients.
更多
查看译文
关键词
Open wedge high tibial osteotomy (owHTO),PEEKPower HTO plate,Hinge fractures
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要