Cardiopulmonary Capacity in Children During Exercise Testing: The Differences Between Treadmill and Upright and Supine Cycle Ergometry.

Tonje Reitan Forbregd, Michelle Arthy Aloyseus,Ansgar Berg,Gottfried Greve

FRONTIERS IN PHYSIOLOGY(2019)

引用 9|浏览5
暂无评分
摘要
Background/Hypothesis: Cardiopulmonary exercise testing (CPET) is used in the assessment of function and prognosis of cardiopulmonary health in children with cardiac and pulmonary diseases. Techniques, such as cardiac MRi, and PET-scan, can be performed simultaneously with exercise testing. Thus, it is desirable to have a broader knowledge about children's normal cardiopulmonary function in different body postures and exercise modalities. The aim of this study was to investigate the effect of different body positions on cardiopulmonary function in healthy subjects performing CPETs. Materials and Methods: Thirty-one healthy children aged 9, 12, and 15 years did four CPETs: one treadmill test with a modified Bruce protocol and three different bicycle tests with different body postures, sitting, tilted 45 degrees, and lying flat (0 degrees). For the bicycle tests, a 20-watt ramp protocol with a pedal frequency of 60 +/- 5 rotations per minute was used. Continous ECG and breath-by-breath (V) over dot O-2 measurements was done throughout the tests. Cardiac structure and function including aortic diameter were evaluated by transthoracic echocardiography prior to the tests. Doppler measurements of the blood velocity in the ascending aorta were measured prior to and during the test. Prior to every test, the participants performed pulmonary function tests with maximum voluntary ventilation test. Results: There is a significantly (p < 0.05) lower peak (V) over dot O-2 in all bicycle tests compared with the treadmill test. There is lower corrected peak (V) over dot O-2 (ml kg(-0.67) min(-1)), but not relative peak (V) over dot O-2 (ml kg(-1) min(-1)), in the supine compared with the upright bicycle test. There are no differences in peak stroke volume or cardiac output between the bicycle modalities when calculated from aortic blood flow. Peak heart rate decreases from both treadmill to upright bicycle and from upright bicycle to the supine test (0 degrees). Conclusion: There are no differences in peak cardiac output between the upright bicycle test and supine bicycle tests. Heart rate and corrected peak (V) over dot O-2 are lower in the supine test (0 degrees) than the upright bicycle test. In the treadmill test, it is a higher absolute and relative peak (V) over dot O-2. Despite the latter differences, we are convinced that both upright and supine bicycle tests are apt in the clinical setting when needed.
更多
查看译文
关键词
cardiopulmonary exercise testing,children's physiology,spirometry,cardiac output,peak (V) over dot O-2,cardiopulmonary capacity,exercise testing
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要