The impact of wall thickness and curvature on wall stress in patient-specific electromechanical models of the left atrium

Biomechanics and Modeling in Mechanobiology(2019)

引用 26|浏览26
暂无评分
摘要
The left atrium (LA) has a complex anatomy with heterogeneous wall thickness and curvature. The anatomy plays an important role in determining local wall stress; however, the relative contribution of wall thickness and curvature in determining wall stress in the LA is unknown. We have developed electromechanical finite element (FE) models of the LA using patient-specific anatomical FE meshes with rule-based myofiber directions. The models of the LA were passively inflated to 10mmHg followed by simulation of the contraction phase of the atrial cardiac cycle. The FE models predicted maximum LA volumes of 156.5 mL, 99.3 mL and 83.4 mL and ejection fractions of 36.9
更多
查看译文
关键词
Left atrium, Cardiac mechanics, Finite element simulation, Patient-specific modeling, Wall stress