Highly Sensitive And Compact Thz Heterodyne Receiver Based On Heb And Qcl At 2.7 Thz

2019 44TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ)(2019)

引用 0|浏览15
暂无评分
摘要
We present the development of a highly sensitise and compact HEB/QCL heterodyne detection system. The HEB mixer is a NbN nano -bridge mounted in an integrated lens-antenna configuration. The local oscillator is a low power consumption and low beam divergence 3rd order distributed feedback quantum cascade laser with single mode emission at the target frequency of 2.7 THZ. A new quasi-optical coupling scheme between the mixer and the local oscillator has been developed that allows the removal of the beam splitter and therefore a better transmission of the RF signal and a more compact detection system. The lowest uncorrected double side band receiver noise temperature of this system is about 880 K.
更多
查看译文
关键词
HEB mixer,NbN nanobridge,integrated lens-antenna configuration,local oscillator,low power consumption,low beam divergence,rd order distributed feedback quantum cascade laser,single mode emission,quasioptical coupling scheme,beam splitter,compact detection system,lowest uncorrected double side band receiver noise temperature,compact THz heterodyne receiver,frequency 2.7 THz,temperature 880.0 K,NbN