METHOD FOR DETECTING AGING RELATED FAILURES OF PROCESS SENSORS VIA NOISE SIGNAL MEASUREMENT

International Journal of Computing(2019)

引用 6|浏览30
暂无评分
摘要
In this article we examine the methods for detecting and predicting aging related process sensor failures by analyzing the noise of the sensor output signal. The study uses data from non-differential and differential pressure transmitters used in the pressure and water level measurements of the reactor pressure vessels of units 1 and 2 of the Olkiluoto nuclear power plant in Finland. The article contains a review of the current methods for detection of sensor failures. Additionally, we present a new method for detecting changes in the sensor output signal. The method creates fingerprints of the power spectra of the sensors by using Principal Component Analysis (PCA). The changes in these fingerprints together with the measurements of the redundant sensors can be used to detect indications of some of the impending sensor failures. In the experimental study we are able to produce stable fingerprints for both the non-differential and differential pressure transmitters. Also, a potential failure in one of the differential pressure transmitters in Olkiluoto unit 2 is detected by inspecting the fingerprints and analyzing the spectral changes of the transmitter output signal.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper