Bulk Anatomical Density Based Dose Calculation for Patient-Specific Quality Assurance of MRI-Only Prostate Radiotherapy.

FRONTIERS IN ONCOLOGY(2019)

引用 15|浏览15
暂无评分
摘要
Prostate cancer treatment planning can be performed using agnetic resonance imaging (MRI) only with sCT scans. However, sCT scans are computer generated from MRI data and therefore robust, efficient, and accurate patient-specific quality assurance methods for dosimetric verification are required. Bulk anatomical density (BAD) maps can be generated based on anatomical contours derived from the MRI image. This study investigates and optimizes the BAD map approach for sCT quality assurance with a large patient CT and MRI dataset. 3D T2-weighted MRI and full density CT images of 54 patients were used to create BAD maps with different tissue class combinations. Mean Hounsfield units (HU) of Fat (F: below -30 HU), the entire Tissue [T: excluding bone (B)], and Muscle (M: excluding bone and fat) were derived from the CT scans. CT based BAD maps (BADBT,CT and BAD(BMF,CT)) and a conventional bone and water bulk-density method (BAD(BW,CT)) were compared to full CT calculations with bone assignments to 366 HU (measured) and 288 HU (obtained from literature). Optimal bulk densities of Tissue for BADBT,CT and Bone for BADBMF, CT were derived to provide zero mean isocenter dose agreement to the CT plan. Using the optimal densities, the dose agreement of BADBT,CT and BADB(MF, CT) to CT was redetermined. These maps were then created for the MRI dataset using auto-generated contours and dose calculations compared to CT. The average mean density of Bone, Fat, Muscle, and Tissue were 365.5 +/- 62.2, -109.5 +/- 12.9, 23.3 +/- 9.7, and -46.3 +/- 15.2 HU, respectively. Comparing to other bulk-density maps, BAD(BMF, CT) maps provided the closest dose to CT. Calculated optimal mean densities of Tissue and Bone were -32.7 and 323.7 HU, respectively. The isocenter dose agreement of the optimal density assigned BADBT,CT and BADB(MF, CT) to full density CT were 0.10 +/- 0.65% and 0.01 +/- 0.45%, respectively. The isocenter dose agreement of MRI generated BAD(BT, MR) and BADBMF,MR to full density CT were -0.15 +/- 0.90% and -0.16 +/- 0.65%, respectively. The BAD method with optimal bulk densities can provide robust, accurate and efficient patient-specific quality assurance for dose calculations in MRI-only radiotherapy.
更多
查看译文
关键词
MRI-only planning,synthetic CT,bulk density,anatomical structure,quality assurance,dosimetric verification
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要