Hidden Hearing Loss And Tinnitus: Utility Of The High-Definition Audiograms In Diagnosis

Jérôme Lefeuvre, Julie Chedeau, Marc Boulet, Gérald Fain,Jean-François Papon,Yann Nguyen,Jérôme Nevoux

CLINICAL OTOLARYNGOLOGY(2019)

引用 6|浏览2
暂无评分
摘要
Tinnitus may be associated with a normal conventional audiogram High-definition audiogram (1 dB in intensity and 1 Hz in frequency precision) can diagnose hidden hearing loss. Tinnitus is often associated with a micro notch or a micro slope on a high-definition audiogram Tinnitus frequency is highly related to micro notch frequency High-definition audiogram provides better characterization of tinnitus testing than the classically used test and could lead to improved treatment guidance.
更多
查看译文
关键词
tinnitus,hearing loss,diagnosis