An Ultra-High-Pressure Liquid Chromatographic Tandem Mass Spectrometry Method for the Analysis of Benzoyl Ester Derivatized Glycols and Glycerol.

JOURNAL OF ANALYTICAL TOXICOLOGY(2019)

引用 3|浏览8
暂无评分
摘要
Presented is an ultra-high-pressure liquid chromatographic tandem mass spectrometry (UPLCMS/MS) method developed for the detection of propylene glycol, glycerol, ethylene glycol and diethylene glycol using isotopically labeled standards in urine as part of ongoing studies to evaluate whether urinary propylene glycol and/or vegetable glycerin concentration are indicators of recent use. Propylene glycol and vegetable glycerol are found in many products that are consumed and used including electronic cigarettes (e-cigarettes). E-cigarettes are battery-powered devices used as an alternative to traditional cigarettes. The liquid formulations aerosolized in these devices largely consist of propylene glycol and/or vegetable glycerol. Published reports regarding the ratio of propylene glycol to glycerol content in these formulations ranged from 50:50 to 100 percent of either. For the analysis of urine specimens from both users and non-users of e-cigarettes, calibrators, controls and specimens were derivatized using benzoyl chloride prior to analysis. They were analyzed using a Waters AcQuity Xevo TQ-S Micro UPLC-MS/MS. Chromatographic separation was performed on an AcQuity UPLC BEH C18 1.7 um, 2.1 x 50 mm, column using a 20 mM ammonium formate in water and 20 mM ammonium formate in methanol as the mobile phase. The method was validated using SWGTOX guidelines for linearity, precision and accuracy, stability, carryover and limit of detection. The linear range was determined using a seven-point calibration curve ranging between 0.5 and 100 mcg/mL. The bias for all validation controls was determined to be +/- 20% of the expected concentrations with CVs of <15%. A total of 124 urine specimens analyzed collected with 50 specimens collected from self-reported nonsmokers (cigarettes/e-cigarettes) confirmed cotinine free using the DRI (R) Cotinine Assay (Thermo Scientific, Waltham, MA) and 74 specimens collected before and after 12 hours self-reported e-cigarettes abstinence e-cigarette users. Propylene glycol and glycerol were determined to have concentration ranges of "none detected" to 1470 and "none detected" to 2950 mcg/mL, respectively.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要