Assessment of deep inspiration breath hold technique setup reproducibility using mega voltage imaging for left breast cancer radiation therapy-integrated network study.

Medical Dosimetry(2020)

引用 3|浏览34
暂无评分
摘要
We evaluated daily setup reproducibility of deep inspiration breath hold (DIBH) using mega voltage (MV) imaging for left breast cancer radiation therapy. Analysis of 109 left breast cancer patients across UPMC Hillman Cancer Center network treated using DIBH technique with daily MV imaging was done. Patient characteristics, MV imaging procedure used and inter-fraction directional shifts were collected. For the statistical analyses, we separated all patients into 2 groups in each of the following 3 categories; (1) obese (BMI ≥ 30) vs nonobese, (2) mastectomy vs lumpectomy, (3) internal mammary node (IMN) treatment vs no IMN treatment. The group mean inter-fraction directional shifts were as following: (1) 0.7 mm (superior), 0.8 mm (inferior); (2) 0.65 mm (left), 0.64 mm (right); (3) 0.89 mm (anterior), 0.83 mm (posterior). Also, any directional shift ≥ 2 mm, ≥ 3 mm, ≥ 4 mm, ≥ 5 mm, ≥ 10 mm was found to be 52.9%, 37.6%, 30.9%, 21.9%, 3.7% of total fractions, respectively. In the stratified analysis, obese patients had larger directional shifts (p < 0.05) and highly associated with number of fractions for ≥ 5 mm in any directional shift compared to nonobese patients (29% vs 17%; p = 0.04). DIBH setup for left breast cancer treatment at our large cancer center network was reproducible with any mean directional shifts less than 1.0 mm using MV imaging. Daily imaging would be more beneficial for obese patients compared to nonobese patients.
更多
查看译文
关键词
DIBH,Set up reproducibility,Visual feedback,Left breast cancer,MV imaging
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要