When pure hydrogen was supplied to the stationary PEMFC generally using the reforming gas, its characteristics were compared with the vehicle PEMFC. The effect of varying the amount of hydrogen supply to the anode on the overall performance was compared. The variation of hydrogen supply in the range of 1.0 similar to 1.7 excess (stoi.) had little effect on the OCV of stationary and vehicle MEA (Membrane and Electrode Assembly). At 0.7 V, the current density of the stationary MEA was about 16% higher than that of the vehicle MEA. I-V performance, impedance, and LSV were measured with varying relative humidity. Both OCV and electrolyte membrane resistances decreased with increasing relative humidity. The hydrogen permeability of the stationary MEA was lower than that of the vehicle MEA, showing that the durability of the stationary membrane could be higher than that of the vehicle membrane.
更多
查看译文
关键词
PEMFC, Stationary, Automobile, MEA, Hydrogen, Performance