Neutron Detection Using Epitaxial 4H-SiC Detector Structures

2018 12th International Conference on Advanced Semiconductor Devices and Microsystems (ASDAM)(2018)

引用 0|浏览26
暂无评分
摘要
In this paper we have focused on detection of neutrons using detector based on 4H-SiC high quality epitaxial layer. The thickness of the active layer was 70 μm and 105 μm. The diameter of Ni/Au circular Schottky contacts were 1.5 mm, and 4.5 mm. The conversion layer was applied on the top detector contact to convert neutron to charge particle. The high density polyethylene and 6LiF were used for detection of fast and thermal neutrons, respectively. The fast 16 MeV neutrons were generated using deuterium-tritium reaction and thermal neutrons were obtained by 239Pu_Be source. The optimal thickness in term of detection efficiency was calculated using MCNPX (Monte Carlo N-particle eXtended) code.
更多
查看译文
关键词
optimal thickness,detection efficiency,neutron detection,4H-SiC detector structures,4H-SiC high quality epitaxial layer,active layer,Ni/Au circular Schottky contacts,conversion layer,detector contact,high density polyethylene,thermal neutrons,MCNPX,Monte Carlo N-particle eXtended,size 1.5 mm,size 4.5 mm,size 105.0 mum,Ni-Au
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要