Ozone comparison between Pandora # 34 , Dobson # 061 , OMI , and OMPS in Boulder , Colorado , for the period December 2013 – December 2016

Atmospheric Measurement Techniques Discussions(2018)

引用 8|浏览8
暂无评分
摘要
A one-time-calibrated (in December 2013) Pandora spectrometer instrument (Pan #034) has been compared to a periodically calibrated Dobson spectroradiometer (Dobson #061) co-located in Boulder, Colorado, and compared with two satellite instruments over a 3-year period (December 2013–December 2016). The results show good agreement between Pan #034 and Dobson #061 within their statistical uncertainties. Both records are corrected for ozone retrieval sensitivity to stratospheric temperature variability obtained from the Global Modeling Initiative (GMI) and Modern-Era Retrospective analysis for Research and Applications (MERRA-2) model calculations. Pandora #034 and Dobson #061 differ by an average of 2.1± 3.2 % when both instruments use their standard ozone absorption cross sections in the retrieval algorithms. The results show a relative drift (0.2± 0.08 % yr−1) between Pandora observations against NOAA Dobson in Boulder, CO, over a 3-year period of continuous operation. Pandora drifts relative to the satellite Ozone Monitoring Instrument (OMI) and the Ozone Mapping Profiler Suite (OMPS) are +0.18± 0.2 % yr−1 and −0.18± 0.2 % yr−1, respectively, where the uncertainties are 2 standard deviations. The drift between Dobson #061 and OMPS for a 5.5-year period (January 2012–June 2017) is −0.07± 0.06 % yr−1.