Geometry of the left ventricular outflow tract assessed by 3D TEE in patients with aortic stenosis: impact of upper septal hypertrophy on measurements of Doppler-derived left ventricular stroke volume

Journal of echocardiography(2018)

引用 6|浏览14
暂无评分
摘要
Background It is unclear how upper septal hypertrophy (USH) affects Doppler-derived left ventricular stroke volume (SV) in patients with AS. The aims of this study were to: (1) validate the accuracy of 3D transesophageal echocardiography (TEE) measurements of the left ventricular outflow tract (LVOT), (2) evaluate the differences in LVOT geometry between AS patients with and without USH, and (3) assess the impact of USH on measurement of SV. Methods In protocol 1, both 3D TEE and multi-detector computed tomography were performed in 20 patients with AS [aortic valve area (AVA) ≤ 1.5 cm 2 ]. Multiplanar reconstruction was used to measure the LVOT short and long diameters in four parts from the tip of the septum to the annulus. In protocol 2, the same 3D TEE measurements were performed in AS patients (AVA ≤ 1.5 cm 2 , n = 129) and controls ( n = 30). We also performed 2D and 3D transthoracic echocardiography in all patients. Results In protocol 1, excellent correlations of LVOT parameters were found between the two modalities. In protocol 2, the USH group had smaller LVOT short and long diameters than the non-USH group. Although no differences in mean pressure gradient, or SV calculated with the 3D method existed between the two groups, the USH group had greater SV calculated with the Doppler method (73 ± 15 vs. 66 ± 15 ml) and aortic valve area (0.89 ± 0.26 vs. 0.73 ± 0.24 cm 2 ) than the non-USH group. Conclusions 3D TEE can provide a precise assessment of the LVOT in AS. USH affects the LVOT geometry in patients with AS, which might lead to inaccurate assessments of disease severity.
更多
查看译文
关键词
Aortic valve stenosis,Echocardiography,Three-dimensional echocardiography,Transesophageal echocardiography
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要