Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study in 1096 patients

European radiology(2019)

引用 23|浏览37
暂无评分
摘要
Background International dose reference levels are lacking for mechanical thrombectomy in acute ischemic stroke patients with large vessel occlusions. We studied whether radiation dose-reduction systems (RDS) could effectively reduce exposure and propose achievable levels. Materials and methods We retrospectively included consecutive patients treated with thrombectomy on a biplane angiography system (BP) in five international, high-volume centers between January 2014 and May 2017. Institutional Review Board approvals were obtained. Technical, procedural, and clinical characteristics were assessed. Efficacy, safety, radiation dose, and contrast load were compared between angiography systems with and without RDS. Multivariate analyses were adjusted according to Bonferroni’s correction. Proposed international achievable cutoff levels were set at the 75th percentile. Results Out of the 1096 thrombectomized patients, 520 (47%) were treated on a BP equipped with RDS. After multivariate analysis, RDS significantly reduced dose–area product (DAP) (91 vs 140 Gy cm 2 , relative effect 0.74 (CI 0.66; 0.83), 35% decrease, p < 0.001) and air kerma (0.46 vs 0.97 Gy, relative effect 0.63 (CI 0.56; 0.71), 53% decrease, p < 0.001) with 75th percentile levels of 148 Gy cm 2 and 0.73 Gy, respectively. There was no difference in contrast load, rates of successful recanalization, complications, or clinical outcome. Conclusion Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety. The respective thresholds of 148 Gy cm 2 and 0.73 Gy represent achievable levels that may serve to optimize current and future radiation exposure in the setting of acute ischemic stroke treatment. As technology evolves, we expect these values to decrease. Key Points • Internationally validated achievable levels may help caregivers and health authorities better assess and reduce radiation exposure of both ischemic stroke patients and treating staff during thrombectomy procedures. • Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety in the setting of acute ischemic stroke due to large vessel occlusion.
更多
查看译文
关键词
Stroke,Thrombectomy,Patient safety
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要