Analysis of capillary microsamples obtained from a skin-prick to measure vancomycin concentrations as a valid alternative to conventional sampling: A bridging study.

Journal of pharmaceutical and biomedical analysis(2019)

引用 8|浏览9
暂无评分
摘要
A bridging study is presented to investigate the applicability of measuring vancomycin concentrations obtained by finger-prick. A total of 25 paired plasma samples, collected from finger prick as capillary microsampling and arterial plasma samples collected from an indwelling cannula as conventional sampling, were obtained from critically ill patients receiving vancomycin. The maximum concentration (Cmax) and the minimum concentration (Cmin) measured were 66.2 mg/L and 29.7 mg/L for capillary microsampling and 78.9 mg/L, 25.6 mg/L for conventional sampling, respectively. The area under the concentration-time curve from 0 to 6 h (AUC0-6h) ranged between 94.8 and 269 mg/L.h for capillary microsampling and from 106 and 303 mg/L.h for conventional sampling. The comparative study conducted was assessed using three different statistical approaches: Bland-Altman and Passing-Bablok regression analyses and the USFDA criterion for the incurred sample reanalysis. The results of this analysis revealed no significant bias and a strong correlation between both sampling methods, with 95% of the calculated concentrations from the paired plasma samples laying within 20% of difference of the mean. This bridging study verifies that capillary microsampling may serve as an alternative to conventional sampling techniques to support clinical applications for measuring vancomycin concentrations in plasma.