A compton spectrometer to monitor the ELI-NP gamma beam energy

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2019)

引用 3|浏览17
暂无评分
摘要
The ELI-NP facility (Extreme Light Infrastructure-Nuclear Physics) will deliver an intense and almost monochromatic gamma beam for frontier research in nuclear physics. Peculiar devices and techniques have been developed to measure and monitor the beam parameters during the commissioning and the operational phase. In this work we will present the Compton Spectrometer, designed to reconstruct the γ beam energy spectrum, by measuring the energy and the position of Compton scattered electrons. The energy and the angle of the scattered electron are measured by a High Purity Germanium detector and a double sided silicon strip detector. The associated photon is detected in coincidence with the electron by barium fluoride (BaF2) crystals for trigger purpose. In this work we report the status of the characterization carried out on the detectors composing the spectrometer.
更多
查看译文
关键词
X-and γ-ray spectroscopy,Electron spectroscopy,Scintillation detectors,Solid-state detectors