Fouling Potential Determination of a UASB Effluent Using Different Assessment Methods

M. Salazar-Peláez,J. M. Morgan-Sagastume,A. Noyola

Journal of Water Chemistry and Technology(2018)

引用 1|浏览5
暂无评分
摘要
The fouling potential of a pilot-scale UASB effluent was determined using different assessment methods (SDI and MFI tests and a mathematical analysis based on a saturation curve model). The UASB reactor was operated at HRT of 4, 8 and 12 h. Although the three methods employed were adequate as a predictive tool for UF membrane fouling, the saturation curve analysis revealed a clearer relationship between the fouling potential of the UASB effluent and the HRT applied. It was found that operating a UASB reactor under short HRT, such as 4 h, could increase membrane fouling in a post-treatment UF module.
更多
查看译文
关键词
modified fouling index, saturation curve model, silt density index, ultrafiltration membrane