Development Of Co-Located Xe-129 And Xe-131 Nuclear Spin Masers With External Feedback Scheme

T. Sato,Y. Ichikawa, S. Kojima, C. Funayama,S. Tanaka,T. Inoue,A. Uchiyama, A. Gladkov,A. Takamine,Y. Sakamoto, Y. Ohtomo,C. Hirao, M. Chikamori,E. Hikota,T. Suzuki, M. Tsuchiya, T. Furukawa, A. Yoshimi, C. P. Bidinosti,T. Ino,H. Ueno,Y. Matsuo, T. Fukuyama, N. Yoshinaga, Y. Sakemi, K. Asahi

PHYSICS LETTERS A(2018)

引用 15|浏览16
暂无评分
摘要
We report on the operation of co-located Xe-129 and Xe-131 nuclear spin masers with an external feedback scheme, and discuss the use of Xe-131 as a comagnetometer in measurements of the Xe-129 spin precession frequency. By applying a correction based on the observed change in the Xe-131 frequency, the frequency instability due to magnetic field and cell temperature drifts are eliminated by two orders of magnitude. The frequency precision of 6.2 mu Hz is obtained for a 10(4) s averaging time, suggesting the possibility of future improliement to approximate to 1 nHz by improving the signal-to-noise ratio of the observation. (C) 2017 Elsevier B.V. All rights reserved.