Measurement of parameters of scintillating bars with wavelength-shifting fibres and silicon photomultiplier readout for the SHiP Muon Detector

JOURNAL OF INSTRUMENTATION(2017)

引用 6|浏览24
暂无评分
摘要
The light yield and the time resolution of different types of 3m long scintillating bars instrumented with wavelength shifting fibres and read out by different models of silicon photomultipliers have been measured at a test beam at the T9 area at the CERN Proton Synchrotron. The results obtained with different configurations are presented. A time resolution better than 800 ps, constant along the bar length within 20%, and a light yield of similar to 140 (70) photoelectrons are obtained for bars 3m long, similar to 4 : 5 (5) cm wide and 2 (0.7) cm thick. These results nicely match the requirements for the Muon Detector of the SHiP experiment.
更多
查看译文
关键词
Photon detectors for UV,visible and IR photons (vacuum) (photomultipliers, HPDs, others),Scintillators,scintillation and light emission processes (solid, gas and liquid scintillators)