Direct determination of oxalic acid by a bare platinum electrode contrasting a platinum nanoparticles-modified glassy carbon electrode
JOURNAL OF EXPERIMENTAL NANOSCIENCE(2016)
摘要
A bare platinum disk electrode without further decoration was directly used to determine oxalic acid (OA), showing good linear ranges of 0.57-104.01 M and 104.01-228.75 M with a low detection limit of 0.38 M (S/N = 3). In contrast, platinum nanoparticles (PtNPs) dispersed on a glassy carbon electrode were successfully achieved by an one-step electrochemical deposition method, possessing relatively wider linear detection ranges of 1.14-342.80 M and 342.80-548.92 M for OA with a lower detection limit of 0.28 M (S/N = 3). Both the proposed electrochemical sensors exhibit great reproducibility, stability and selectivity. In particular, they have been applied to the determination of OA in real spinach samples, showing excellent analytical performance.
更多查看译文
关键词
oxalic acid sensor,electrochemical determination,constant potential amperometry,platinum nanoparticles,modified electrode