Development and commissioning of the 30 ps time resolution MEG II pixelated Timing Detector

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT(2019)

引用 2|浏览98
暂无评分
摘要
The MEG II experiment is designed to improve by an order of magnitude the sensitivity of 4.2 x 10(-13) reached by MEG on the search for mu(+) -> e(+) gamma decay. A pixelated Timing Counter (pTC) has been developed to improve the time resolution by measuring the positron time information independently with several counters. We constructed and installed the pTC and performed commissioning runs at the pi E5 beam line at PSI. A resolution of 38.5 ps is obtained with commissioning run data.
更多
查看译文
关键词
Timing detectors,SiPM,Scintillator Detectors