Measurement Variability Of Persistent Pulmonary Subsolid Nodules On Same-Day Repeat Ct: What Is The Threshold To Determine True Nodule Growth During Follow-Up?

PLOS ONE(2016)

引用 19|浏览9
暂无评分
摘要
PurposeTo assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics.MethodsTwo same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons.ResultsMeasurement variability for the longest and average diameter of SSNs was +/- 1.3 mm (+/- 13.0%) and +/- 1.3 mm (+/- 14.4%) in situation 1, and +/- 2.2 mm (+/- 21.0%) and +/- 2.1 mm (+/- 21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was +/- 1.2 mm (+/- 27.1%) and +/- 0.8 mm (+/- 24.0%) in situation 1, and +/- 3.7 mm (+/- 61.0%) and +/- 1.5 mm (+/- 47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001).ConclusionsA cutoff of +/- 2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs' change when readers of initial and follow-up CT were different.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要