Whole blood samples for adrenocorticotrophic hormone measurement can be stored at room temperature for 4 hours.

Mette Christensen, Rikke Fogt Madsen, Line Rosengreen Møller,Cindy Soendersoe Knudsen,Mie Hessellund Samson

Scandinavian journal of clinical and laboratory investigation(2016)

引用 9|浏览2
暂无评分
摘要
The comparison between samples stored at room temperature for up to 4 h and standard conditions showed that ACTH samples do not require cooling until centrifugation, if a mean difference in ACTH concentration of -4.3%, between the individual results, can be accepted.
更多
查看译文
关键词
ACTH,corticotrophin,hormones,ice,plasma,pre-analytical,protein stability,storage,temperature