Robust sensing suite for measuring temporal dynamics of surface temperature in sewers

SCIENTIFIC REPORTS(2018)

引用 26|浏览16
暂无评分
摘要
Sewerage systems are paramount underground infrastructure assets for any nation. In most cities, they are old and have been exposed to significant microbial induced corrosion. It is a serious global problem as they pose threats to public health and economic repercussions to water utilities. For managing sewer assets efficaciously, it is vital to predict the rate of corrosion. Predictive models of sewer corrosion incorporate concrete surface temperature measurements as an observation. However, currently, it has not been fully utilized due to unavailability of a proven sensor. This study reports the feasibility of infrared radiometer for measuring the surface temperature dynamics in the aggressive sewer conditions. The infrared sensor was comprehensively evaluated in the laboratory at different environmental conditions. Then, the sensor suite was deployed in a Sydney based sewer for three months to perform continuous measurements of surface temperature variations. The field study revealed the suitability of the developed sensor suite for non-contact surface temperature measurements in hostile sewer conditions. Further, the accuracy of the sensor measurements was improved by calibrating the sensor with emissivity coefficient of the sewer concrete. Overall, this study will ameliorate the present sewer corrosion monitoring capabilities by providing new data to models predicting sewer corrosion.
更多
查看译文
关键词
Concrete Sewer,Surface Temperature Measurements,Sewing Conditions,Mean Absolute Percentage Error (MAPE),Sensor Enclosure
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要