Temporal Uptake Patterns of 18F-Fluorocholine Among Hyperfunctioning Parathyroid Glands.

CLINICAL NUCLEAR MEDICINE(2018)

引用 15|浏览0
暂无评分
摘要
Optimal scan time of F-18-fluorocholine (FCH) PET/CT for localization of hyperfunctioning parathyroid glands is poorly documented. We report a small series of 9 histologically proven hyperfunctioning parathyroid gland with heterogeneous temporal uptake profile. Thirty-minute dynamic acquisition starting just after F-18-fluorocholine administration and delayed acquisition were recorded. Three different uptake patterns are seen (early washout, stable uptake, late increase) indicating the importance of an early (5-10 minutes) acquisition. A late acquisition (60 minutes) could be useful when the early acquisition is negative. No correlations were noted between uptake profile and histological or genetic results.
更多
查看译文
关键词
parathyroid glands,FCH,PET